Four Cover Families. One Engineered Portfolio.

TE Connectivity’s WAP portfolio covers the four exposed asset geometries that drive the majority of distribution wildlife events — insulator covers, bushing covers, conductor and jumper covers, substation wildlife mitigation — with substation-class configurations where station-level mitigation is in scope. Each family is engineered for its specific asset geometry, hot-stick installable, UV-stable, and dielectrically rated for the distribution-class voltages it covers.

TE WAP raptor protection cover for distribution insulator wildlife mitigation

Insulator Covers

Deadend / Line Post / Suspension. 15 kV / 25 kV / 35 kV.

TE WAP polymer bushing cover for transformer and breaker wildlife protection

Bushing Covers

Transformer / Breaker / Substation. Distribution & station-class.

TE WAP polymer conductor and jumper cover for overhead distribution

Conductor & Jumper

Overhead conductor and jumper covers.

TE WAP substation wildlife mitigation cover for station-class apparatus

Substation Mitigation

Disconnect, station-class apparatus configurations.

Deadend, Line Post, Suspension — Engineered for the Distribution Insulator Geometries That Drive Wildlife Events.

Insulator covers are the foundation of most WAP wildlife mitigation programs because distribution insulator geometries are where the highest count of wildlife events occur. WAP insulator covers are available across standard distribution voltage classes — 15 kV, 25 kV, and 35 kV — with custom sizing for non-standard insulator geometries, and across the three principal insulator configurations: deadend, line post, and suspension.

TE WAP deadend insulator cover for distribution-class wildlife mitigation 15 kV to 35 kV

Deadend Insulator Covers

Polymer cover bodies engineered for deadend insulator geometries at standard distribution voltage classes. Covers the energized hardware exposure on the deadend assembly directly.

TE WAP line post insulator cover hot-stick installable on energized distribution

Line Post Insulator Covers

Covers engineered for line post insulator configurations — typically the highest-count distribution insulator type on a feeder. Hot-stick installable on energized assets.

TE WAP suspension insulator cover for distribution assemblies

Suspension Insulator Covers

Polymer covers for suspension insulator assemblies at distribution voltages. Covers the suspension hardware geometry and the points where wildlife contact most commonly occurs.

Standard 15 kV / 25 kV / 35 kV across deadend, line post, suspension configurations. Custom sizing available for non-standard insulator geometries.

Hot-stick installable. Field-install time measured in minutes per asset for standard configurations. No de-energization required on most distribution applications — verify per utility procedure.

Transformer, Breaker, and Substation Bushing Covers — Engineered for the Apparatus Geometries That Drive Flashover Events.

Bushing flashover events are a measurable share of substation forced outages on Canadian utility networks — high-consequence events that drive station-level reliability metrics. WAP bushing covers address the geometries directly: transformer bushings on distribution-class transformers, breaker bushings on distribution-class breakers and reclosers, and substation-class bushing covers for station apparatus.

TE WAP transformer bushing cover for distribution-class transformer wildlife protection

Transformer Bushing Covers

Polymer covers for distribution-class transformer bushings. Covers the energized bushing exposure on overhead, padmount, and substation transformers.

TE WAP breaker bushing cover for distribution-class breakers, reclosers, switchgear

Breaker Bushing Covers

Covers for distribution-class breakers, reclosers, and switchgear bushings. Stops the flashover pattern at switching gear directly.

TE WAP polymer bushing cover for transformer and breaker wildlife protection

Substation Bushing Covers

Station-class bushing covers for substation apparatus geometries — typically a higher-value-per-asset investment than distribution-class cover work, with corresponding reliability impact.

Distribution-class and station-class configurations. Custom sizing for non-standard bushing geometries.

Hot-stick installable on distribution-class. Substation-class installations confirmed per utility procedure and applicable safety standard.

Polymer Covers for the Exposed Conductor and Jumper Sections Where Animals Bridge Phases.

Wildlife events on conductor and jumper sections happen at the points where the energized conductor footprint is exposed and small animals can bridge phase-to-phase or phase-to-ground — typically at junctions, deadend assemblies, and jumper sections between transformer or switchgear connections. WAP conductor and jumper covers reduce the exposed energized footprint at those points.

Polymer covers for overhead conductor sections and jumper geometries at distribution voltages.

Hot-stick installable. Engineered for field-install time measured in minutes per asset.

Cover Configurations Engineered for Substation Apparatus and Switchgear Geometries.

Substation wildlife events drive a separate consequence profile from distribution events — typically higher customer-minutes-out per event and higher station-level reliability impact. WAP substation cover configurations are engineered for the apparatus and switchgear geometries that drive substation wildlife outages: disconnect switches, distribution-class breakers, station-class apparatus, and the equipment combinations that drive substation flashover events.

Substation specification work is typically coordinated with TE’s substation application engineering team through Rexel Utility’s specialist contact pathway. Cover configurations are engineered per substation per application, with TE engineering involvement at the specification stage for non-standard work.

substation wildlife and asset protection from TE

Cover Installation Training That Makes WAP Perform the Same Way on Every Crew.

Cover programs share a recurring failure mode with most utility hardware programs: the right product specified, the wrong installation practice in the field. TE’s Technical Engagement & Training program is engineered to close that gap for WAP by transferring cover installation practice into crews — at the utility’s own operating centres.

Utility Seminars

Technical sessions at utility operating centres on wildlife mitigation program design, feeder asset selection, cover family specification, standards compliance documentation.

On-Site Cover Installation Demonstrations

Hands-on demonstrations at utility yards covering hot-stick installation technique, product handling, and specification questions raised during the demonstration.

Training Trailer Visits

TE deploys a dedicated training trailer to utility operating centres for full-day or multi-day engagements with product samples and live installation practice across WAP cover families.

ANSI. IEEE. CSA. Engineered and Tested to the Specs Utilities Specify.

WAP polymer covers are engineered and tested to ANSI, IEEE, and CSA standards where applicable. Specific standards compliance per cover family is documented in TE’s application notes and confirmed by TE engineering during the specification conversation.

ANSI / IEEE: Across cover dielectric, mechanical performance, and weathering specifications.

CSA: Canadian standards compliance for covers specified into Canadian utility applications.

Utility specification practice: WAP covers are widely included in Canadian utility wildlife mitigation standards by name.

Technical documentation: Application notes, installation instructions, dielectric test reports available through Rexel Utility’s specialist team.

ANSI logo
IEEE logo
CSA Group logo

Ready to Spec WAP on Your Wildlife Mitigation Program?

Whether you’re scoping insulator covers for a worst-hit-feeder pilot, specifying bushing covers for a substation wildlife mitigation rollout, or scoping conductor covers for a feeder hardening program, the path is the same: talk to a Rexel Utility specialist.

Frequently Asked Questions

WAP’s deadend insulator cover family is engineered for deadend insulator geometries at standard distribution voltage classes — 15 kV, 25 kV, and 35 kV. Polymer cover bodies cover the energized hardware exposure on the deadend assembly directly. Custom sizing is available for non-standard deadend geometries through TE engineering.

Yes. WAP transformer bushing covers are engineered for hot-stick installation on energized distribution-class transformer bushings, with no de-energization required for most distribution applications. Substation-class transformer bushing installations are confirmed per utility procedure and applicable safety standard during the specification work with TE engineering.

WAP cover families ship in standard configurations for typical distribution and substation geometries, with custom sizing available for non-standard work through TE engineering. Specification of non-standard cover configurations is coordinated through Rexel Utility’s specialist contact pathway in coordination with TE’s WAP application engineering team.

WAP polymer covers are engineered and tested to ANSI, IEEE, and CSA standards where applicable across the cover families. Specific standards per family are documented in TE’s application notes and confirmed by TE engineering during the specification conversation through Rexel Utility’s specialist team.

The WAP training trailer engagement covers hot-stick installation technique on the cover families, product handling, hands-on installation practice on product samples, and specification questions raised during the session. Typical engagements are one or two full days at a utility operating centre, coordinated through Rexel Utility’s specialist contact pathway.

TE WAP application engineers engage during the program-design stage for feeder asset selection, cover family specification, and field-deployment sequencing. Engagement is coordinated through Rexel Utility’s regional account manager and is part of the standard supply relationship for wildlife mitigation program work — not a separate aftermarket service.